Selecting the Proper Mist Eliminator
|
Using the Flow Capacities chart below, select your lowest operating pressure at the point of installation and read down that column to the nearest flow that meets or exceeds your requirements. Find the nearest flow in the operating pressure column. Follow along the row to the left side of the chart to determine the proper model number. For inlets other than 100° F, multiply your required capacity by the applicable correction factor to the left. |
| Model | 50 PSIG |
60 PSIG |
70 PSIG |
80 PSIG |
90 PSIG |
100 PSIG |
110 PSIG |
120 PSIG |
130 PSIG |
140 PSIG |
150 PSIG |
| VME-125 | 95 | 110 | 125 | 140 | 155 | 170 | 185 | 200 | 215 | 230 | 245 |
| VME-250 | 190 | 220 | 250 | 280 | 310 | 340 | 370 | 400 | 425 | 460 | 490 |
| VME-500 | 380 | 440 | 500 | 560 | 615 | 675 | 740 | 790 | 850 | 915 | 975 |
| VME-850 | 645 | 745 | 850 | 955 | 1045 | 1150 | 1255 | 1345 | 1450 | 1550 | 1655 |
| VME-1250 | 945 | 1100 | 1250 | 1405 | 1540 | 1690 | 1840 | 1975 | 2130 | 2280 | 2430 |
| VME-1500 | 1134 | 1320 | 1500 | 1685 | 1845 | 2025 | 2210 | 2370 | 2555 | 2735 | 2920 |
| VME-2000 | 1515 | 1755 | 2000 | 2245 | 2460 | 2700 | 2945 | 3160 | 3405 | 3645 | 3890 |
| VME-2500 | 1890 | 2195 | 2500 | 2805 | 3075 | 3375 | 3680 | 3950 | 4255 | 4560 | 4860 |
| VME-3000 | 2268 | 2635 | 3000 | 3365 | 3685 | 4050 | 4415 | 4740 | 5105 | 5470 | 5835 |
| VME-5000 | 3780 | 4390 | 4995 | 5605 | 6145 | 6750 | 7360 | 7900 | 8505 | 9115 | 9720 |
| VME-7500 | 5670 | 6585 | 7495 | 8405 | 9215 | 10,125 | 11,040 | 11,850 | 12,760 | 13,670 | 14,580 |
| VME-10,000 | 5670 | 6585 | 7495 | 8405 | 9215 | 10,125 | 11,040 | 11,850 | 12,760 | 13,670 | 14,580 |