Selecting the Proper Pipeline Natural Gas Dryer

 Model Suffix   Max. Working Pressure 
2.8 280 PSIG
7.2 720 PSIG

In the Dryer Capacities chart, locate the column for the minimum operating pressure and read down to the capacity (in Mcfd) that meets or exceeds your requirement. Next, find the corresponding dryer model group in the left column. From that model group, choose the specific model that meets or exceeds your maximum anticipated operating pressure based on the following model suffixes using the chart to the left.

Model  10 
 PSIG 
 25 
 PSIG 
 50 
 PSIG 
 100 
 PSIG 
 200 
 PSIG 
 280 
 PSIG 
 500 
 PSIG 
 720 
 PSIG 
 PLD 8-2.8 
 PLD 8-7.2 
15
15
25
25
40
40
65
65
120
120
150
150
---
300
---
420
 PLD 12-2.8 
 PLD 12-7.2 
30
30
50
50
80
80
140
140
265
265
325
325
---
630
---
900
 PLD 16-2.8 
 PLD 16-7.2 
50
50
80
80
125
125
225
225
415
415
510
510
---
1000
---
1450
 PLD 20-2.8 
 PLD 20-7.2 
75
75
125
125
200
200
350
350
660
660
810
810
---
1575
---
2250
 PLD 24-2.8 
 PLD 24-7.2 
110
110
175
175
285
285
500
500
935
935
1150
1150
---
2230
---
3200
 PLD 36-2.8 
 PLD 36-7.2 
275
275
415
415
675
675
1200
1200
2230
2230
2750
2750
---
5360
---
7700

  • For high pressure applications, Contact Us.